Ultrasonic Flowmeters: Clamp-On vs. In-Line

Titan Enterprises, UK-based manufacturer and supplier of liquid flow measuring solutions, explains the advantages and disadvantages of clamp-on and in-line ultrasonic flowmeters and the process applications most suited for these types of measuring devices.

Ultrasonic Flowmeters represent a significant advancement in flow measurement technology, offering precision, versatility and ease of use, with no moving or internal components. Providing improved electronic processing, increasing diagnostics and excellent accuracy, ultrasonic flowmeters operate using ultrasound to measure the velocity of a fluid flowing through a pipe of known dimensions giving the volumetric flow. There are two main types:

  1. Transit-time or ‘time of flight’ ultrasonic flowmeters: measure the time difference between ultrasonic pulses sent in the direction of the flow and against the flow. The difference in the transit time is directly proportional to the flow velocity.
  2. Doppler ultrasonic flowmeters: measure the frequency shift of an ultrasonic signal reflected by particles or bubbles in the fluid. This frequency shift is used to calculate flow velocity.

Ultrasonic flowmeters can be either integrated into a pipe to measure the stream of flow ‘in-line’ or clamped onto the outside of an existing pipe. In-line and clamp-on flowmeters are both commonly used for measuring the flow rate of liquids and gases in various applications. Each type has its own set of advantages and disadvantages, which makes them suitable for different industrial applications.

 In-line flowmeters are preferred for applications requiring high accuracy, as they are inserted directly into the pipe, enabling data from multiple sensors to be used for precise flow rate measurement. Their consistent performance over time also makes them suited for applications requiring stable, long-term measurement. Other advantages include that they can be independently and finely calibrated to be directly relatable to final installation. In-line flowmeters are made for both liquid and gas flow measurements and can handle high pressures and temperatures, depending on the construction material and design.

However, as in-line flowmeters are inserted directly into the pipe, installation can be time consuming, costly and disruptive. Maintenance can be similarly difficult and may require disassembling parts of the pipe for access. Once installed they are not easily relocated, making them a less flexible choice.

Despite in-line flowmeters’ higher installation costs, being electronic devices, their lifetime costs are relatively low. They are often used in Custody Transfer industries, such as oil and gas, as the high accuracy over time and the low maintenance costs recoup the initial installation expense fairly quickly.

 Clamp-on flowmeters are installed non-invasively on an existing pipe and are therefore low-maintenance. In addition, clamp-on flowmeters can be fitted to a variety of pipe sizes, including large pipe diameters, and can be used on a variety of fluids. They can also be moved to different measurement points, providing flexibility for temporary installations or spot-check measurements.

Clamp-on flowmeters typically have a lower accuracy than their in-line counterparts, influenced by both the pipe and fluid characteristics. Calibration can only be done on a representative piped system and not on the final installed device, further compromising the accuracy attainable. In addition, they can be susceptible to signal interference from nearby electronic equipment, which can also affect measurement reliability.

While clamp-on flowmeters may offer lower accuracy, they are ideal for non-invasive, flexible and portable applications where ease of installation and low installation costs are priorities and where the process cannot be interrupted.

The choice between ultrasonic in-line and clamp-on flowmeters depends on the specific needs of the application, including factors such as required accuracy, ease of installation, maintenance considerations, and the nature of the fluid and pipeline.

Titan’s range of in-line ultrasonic flowmeters utilise patented ‘time-of-flight’ ultrasonic technology, operating with excellent accuracy over wide liquid flow ranges from 2 ml/min to 20 l/min.