Sensors are the eyes and ears of process operators, providing crucial, actionable data, but adopting them is often seen as complex and disruptive. Here, Turck Banner redefines process-sensing technology and shares how to benefit from sensors without invasive installation or extensive coding.
Process sensor is a broad term, which typically evokes the physical properties that are measured in processing industries rather than the sensors themselves. For this reason, Turck Banner Ltd, a sensing system and industrial/process automation expert, has sought to more clearly define what is often referred to as Process Sensor Solutions as Measuring Sensor Solutions, a term that can be more universally understood, to describe sensing technology and its applications.
As the full range of measurable properties is too vast to cover here, this article will concentrate on three commonly found in food and beverage processing: Temperature, Level and Flow.

Temperature
Temperature can be measured either with contact probes or remotely with infrared detection.
Contact probes typically use either thermocouples or resistance. They have a wide temperature range -200°C to +1800° and have high accuracy and stability, but require contact with the medium being measured. Infrared sensors (Pyrometers) work by detecting infrared radiation emitted by an object.
While typical sensors have a temperature range of -20°C to +300°C, more specialised sensors can measure up to 3000°C. They have a fast response (75mS) and an accuracy of 1°C or 2°C. They are non-contact, can measure the temperature from up to 1 metre away, and can also be used to detect the presence or position of moving hot objects, such as food exiting an oven, or hot glue detection on a packing box.
In a factory producing waffles, for example, it is imperative that iron to be hot before the batter is poured into it or the result will be an inconsistently prepared product. To ensure that a griddle is at temperature, a non-contact temperature sensor, such as the T-GAGE M18T, is aimed at the cooking surface to detect that the surface is hotter than the surrounding air. If the waffle iron is hot, the batter will be poured in and the process will continue; if not, the T-GAGE temperature sensor output won’t trigger the batter release mechanism allowing the iron additional time to heat.
Level
Measuring the level of solids or liquids in a tank, silo or other container is essential in food processing to ensure process efficiency by preventing over or under filling, maintains product quality and helps reduce waste. Level measurement can be divided into Point level and Continuous categories, which subdivide into Contact and Non-contact.
Point level detects when the material has reached a certain point and continuous level where the level of the material is measured over a range, and the sensor output is either analogue or digital data.
Point level is often used for either pump in/out control or as a call for manual fill. When low level is detected, the pump is turned on to fill the tank, or an alarm is given for the tank to be manually filled by the operator. When the level reaches the high level, the pump switches off or the operator is warned that the tank is at the desired level.
Typical sensors for point level include optical, either looking through a sight glass or down on to the material surface (Non-contact); float switches, which sit on a liquid surface and activates a switch (Contact); and capacitive, which detects change between the (non-metallic) tank wall and liquid (Non-Contact).
Continuous level measurement, as the name suggests, continually measures the level of a material in container and uses a wider range of sensors to do so:
Probes work on a principal of conduction, either electrical or microwave. The probe or probes extend into the liquid and the liquid conducts the energy to a second probe or metal tank wall. The amount of conduction increases with the length of probe covered by the liquid. They can be used in pressure tanks but need a liquid with a dielectric constant greater than 1.8 (Contact).
Ultrasonic work by bouncing a sound wave off the surface of the medium and measuring the time of flight. They can have either an analogue output or digital data and require a medium that does not absorb sound (Non-contact).
Radar sensors work in a similar way to ultrasonic but use pulses in the GHz frequency band. They are accurate, and are not affected by surface foam, temperature or pressure. Different frequency versions are available to detect different materials. Radar sensors are often a good substitute for ultrasonic and have analogue and digital data outputs (Non-contact).
Optical (laser point and laser area scanning): optical sensors and laser point sensors measure the distance to a point or small area on the target material, with switched, analogue, and digital data outputs (Non-contact).
Area scanning laser sensors measure the distance to tens of thousands of points in an area and can output the peak height and percentage fill of a container. They are a good choice for containers with an irregular fill level, or containers with randomly sized items.
Flow
Flow sensors are typically contact type sensors used to measure the movement of liquid through a production process, as in the brewing of beer, for example, and take the following forms:
Mechanical Moving: the fluid either turns a rotor and the rotational speed is used to calculate the flow, or the fluid moves a piston in an internal chamber and the amount of movement is used to calculate the flow
Differential Pressure: a flow restriction is used, which creates a pressure drop and the pressure is measured either side of the restriction. The flow rate is calculated in relation to the size of the pressure difference; for this reason it is not suitable for low flow rates.
Calorimetric (heat transfer): the flow of the medium over the probe transfers heat from one side to the other. The amount of heat transferred is proportional to the flow rate. The temperature of the medium is also measured.
There are many other types of flow sensors, such as electromagnetic for conductive materials, ultrasonic using the Doppler Effect, and vortex detection.
Simplicity
While many factories are moving towards full IoT, it is still common for automation to occur in isolated pockets around a facility. This is particularly prevalent in operations that have evolved overtime, adopting new technologies as the need arises. This can result in isolated systems consisting of current and legacy devices, from various suppliers, often with incompatible data protocols.
Fortunately, PWM (Pulse Width Modulation) or PFM (Pulse Frequency Modulation) are built in to many sensors and indicators, removing the requirement for a PLC (Programmable Logic Controller). Further to this, signal converters from Turck Banner’s “SNAP” range can change Analogue to PFM/PWM outputs. This allows previously incompatible devices to be connected, so that data can be shared between them.
Turck and Banner Engineering combined have the widest range of sensors in the world. Its daughter company, Turck Banner Ltd, are able to offer solutions to fit everything from a simple cost effective, stand-alone sensor and indicator, through to a fully networked turnkey solution.
The company designs with ease of use in mind, maintaining that measurement sensor solutions should solve problems rather than create new challenges.